{"id":1756,"date":"2025-12-10T11:26:07","date_gmt":"2025-12-10T10:26:07","guid":{"rendered":"https:\/\/bioeducator.eu\/?page_id=1756"},"modified":"2025-12-10T11:26:09","modified_gmt":"2025-12-10T10:26:09","slug":"protein-determination-methods","status":"publish","type":"page","link":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en","title":{"rendered":"Protein determination methods"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Knowledge of the protein content in a sample is essential in the laboratory. It allows many other laboratory tests (e.g. <a href=\"https:\/\/bioeducator.eu\/?page_id=1712\">SDS-PAGE<\/a>) to be performed correctly and purification conditions (e.g. <a href=\"https:\/\/bioeducator.eu\/?page_id=1555&amp;lang=en\">chromatographic<\/a> column loading) to be selected. It is also an important measurement during protein production. It enables the preparation of appropriate dilutions and monitoring of the purification process.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1024x683.jpg\" alt=\"ELISA test on 96 well plate\" class=\"wp-image-1178\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1024x683.jpg 1024w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-300x200.jpg 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-768x512.jpg 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-391x260.jpg 391w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1536x1024.jpg 1536w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-2048x1365.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>There are several protein determination methods. They use different mechanisms and vary in sensitivity, accuracy, and speed of measurement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. UV-VIS Absorbance Measurement at a Wavelength of 280 nm<\/h2>\n\n\n\n<p>The basis for the <a href=\"https:\/\/bioeducator.eu\/?page_id=1612&amp;lang=en\">absorbance measuremen<\/a>t method at a wavelength of 280 nm is the ability of aromatic amino acids (tryptophan, tyrosine and phenylalanine) to absorb light with a maximum at a wavelength of 280 nm. According to Lambert-Beer&#8217;s law, absorbance is proportional to protein concentration (A=\u0435Cl). For pure samples, knowing the extinction coefficient, we are able to accurately measure the protein content in the sample.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"213\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Tyrosine-300x213.png\" alt=\"Tyrozyna\" class=\"wp-image-1743\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Tyrosine-300x213.png 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Tyrosine-768x544.png 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Tyrosine.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Tyrosine<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"224\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/tryptophan-300x224.png\" alt=\"tryptofan\" class=\"wp-image-1742\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/tryptophan-300x224.png 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/tryptophan-768x573.png 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/tryptophan.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Tryptophan<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"250\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/phenyloalanine-1-300x250.png\" alt=\"\" class=\"wp-image-1746\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/phenyloalanine-1-300x250.png 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/phenyloalanine-1-768x640.png 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/phenyloalanine-1.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Phenyloalanine<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p>The method of measuring absorbance at a wavelength of 280 nm has a disadvantage. Each protein has a different amino acid composition and a different content of aromatic amino acids. In the case of very complex samples or when amino acids or nucleic acids are present in the matrix, the result is inaccurate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Microbiuret Method<\/h2>\n\n\n\n<p>The microbiuret method is a modification of the traditional biuret method. However, it allows for measurements to be taken on smaller sample volumes. The technique is based on the reaction of peptide bonds with copper ions in a strongly alkaline environment. A minimum of two peptide bonds are required for the reaction to occur. Free amino acids or dipeptides will therefore not give a positive result. Contrary to appearances, the name of the method does not come from burette, but from biuret. Biuret is the simplest compound that gives a positive reaction.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Biuret_structure-300x300.png\" alt=\"Biuret\" class=\"wp-image-1739\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Biuret_structure-300x300.png 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Biuret_structure-150x150.png 150w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Biuret_structure-768x768.png 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Biuret_structure.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Biuret<\/figcaption><\/figure>\n<\/div>\n\n\n<p>The reaction was described in 1833 by Ferdinand Rosi and independently in 1857 by Gustaw Piotrowski. The result is independent of the amino acid composition of the protein. The reaction produces a coloured copper-protein complex (purple). It exhibits maximum absorption at wavelengths of 310 nm and 505 nm. Measurement at a wavelength of 310 nm may be less sensitive due to the possibility of interference. For this reason, the measurement is often performed at a wavelength of 540 nm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Lowry method<\/h2>\n\n\n\n<p>The Lowry method is an improvement on the biuret method. It is based on a two-step chemical reaction. The first reaction is a typical Piotrowski reaction used in the biuret method. The reaction between peptide bonds and copper ions produces coloured complexes.<\/p>\n\n\n\n<p>The second reaction uses the Folin\u2013Cocalteu reagent. This reagent is typically used to detect aromatic amino acids in proteins (tyrosine and tryptophan). The reaction is based on the reduction of phosphotungstic and phosphomolybdic acid salts by aromatic amino acid residues and copper complexes. The reaction takes place in an alkaline environment (pH 10). This results in the formation of coloured products. The intensity of the colour is directly proportional to the amount of protein.<\/p>\n\n\n\n<p>The method is very sensitive. It allows the detection of as little as 1 \u03bcg\/ml of protein. It is approximately 100 times more sensitive than the biuret method. Unfortunately, due to the participation of tyrosine and tryptophan in the reaction, its result depends on the amino acid composition of proteins.<\/p>\n\n\n\n<p><strong>Note: The reaction occurs at pH 10. Under these conditions, phosphomolybdic acid is unstable and quickly reduces to orthophosphoric acid. For this reason, the sample must be mixed quickly to ensure that the phosphomolybdic acid reacts with the protein.<\/strong><\/p>\n\n\n\n<p>The reaction produces a blue colour that can be measured at a wavelength of 650\u2013750 nm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Bradford method (Coomassie Brilliant Blue G-250 dye)<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>The Bradford method is one of the most commonly used techniques. It is fast and at the same time provides fairly high sensitivity. The technique is based on the reaction of Coomassie Brilliant Blue G-250 dye with proteins. The reaction, which takes place in an acidic environment, involves the formation of ionic and hydrophobic bonds with certain amino acids. Arginine reacts mainly with the dye, and to a lesser extent also histidine, lysine, tyrosine, tryptophan and phenylalanine. The resulting complex is blue with a maximum absorption at a wavelength of 595 nm. The measurement is extremely simple. Simply add the reagent to the sample and read the result after about 5 minutes. Similar to the Lowry method, Bradford method may give different results depending on the protein due to differences in amino acid composition. In addition, some detergents such as SDS, Triton-X or Tween may react with the reagent and produce an interfering colour.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Bradford_protein_assay-1024x768.jpg\" alt=\"Bradford assay\" class=\"wp-image-1740\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Bradford_protein_assay-1024x768.jpg 1024w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Bradford_protein_assay-300x225.jpg 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Bradford_protein_assay-768x576.jpg 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Bradford_protein_assay-1536x1152.jpg 1536w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Bradford_protein_assay-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Test Bradforda na p\u0142ytce 96 do\u0142kowej<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Coomasie-brilliant-blue-G250-300x300.png\" alt=\"Coomasie Brilliant Blue G-250\" class=\"wp-image-1741\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Coomasie-brilliant-blue-G250-300x300.png 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Coomasie-brilliant-blue-G250-150x150.png 150w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Coomasie-brilliant-blue-G250-768x768.png 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/Coomasie-brilliant-blue-G250.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Coomasie Brilliant Blue G250<\/figcaption><\/figure>\n<\/div>\n\n\n<p><a href=\"Note: If the sample contains detergents (e.g. cell lysates, membrane proteins), it is advisable to use a blank sample with added detergents to eliminate interference.\">Note: If the sample contains detergents (e.g. cell lysates, membrane proteins), it is advisable to use a blank sample with added detergents to eliminate interference.<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">BCA (Bicinchoninic Acid) method<\/h2>\n\n\n\n<p>The BCA method is a modification of the Lowry method. Like the Lowry method, it is a two-step process. In the first stage, the Piotrowski reaction takes place. Peptide bonds reduce copper ions. These react with bicinchoninic acid (BCA). The result is a stable purple-coloured complex. The absorbance of the product is measured at a wavelength of 566 nm.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/BCA_acid-300x300.png\" alt=\"Kwas BCA\" class=\"wp-image-1744\" srcset=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/BCA_acid-300x300.png 300w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/BCA_acid-150x150.png 150w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/BCA_acid-768x768.png 768w, https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/12\/BCA_acid.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Bicinchonic acid (BCA)<\/figcaption><\/figure>\n<\/div>\n\n\n<p>The BCA method is very sensitive. It detects lower protein concentrations than the Lowry method, and at the same time its result does not depend on the amino acid composition, as is the case with the Bradford method. The disadvantage is that it is sensitive to the presence of reducing agents in the sample and to the presence of chelating agents such as EDTA.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Comparison of Protein Content Determination Methods<\/h2>\n\n\n\n<p>Individual protein determination methods differ in terms of sensitivity, speed of execution, accuracy of results, and vulnerability to interference from matrix components. The table below will help you make your choice.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Methods<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Sensitivity and range<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Test duration<\/strong><\/td><td><strong>Accuracy<\/strong><\/td><td><strong>Interference<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Absorbance measurment at 280 nm<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Low (0,1 \u2013 3 mg\/ml)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Very quick<\/td><td>Average (depending on protein composition)<\/td><td>Susceptible to contamination with nucleic acids and amino acids.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Microbiuret method<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Low (1 \u2013 10 mg\/ml)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Average (10 \u2013 20 minut)<\/td><td>High (independent of protein composition)<\/td><td>Resistant to matrix composition<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lowry method<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">High (0,01 \u2013 1 mg\/ml)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Long (40 \u2013 60 minut)<\/td><td>High (depends partly on composition)<\/td><td>Susceptible to contamination with detergents<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Bradford method<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">High (0,005 \u2013 2 mg\/ml)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Quick (~ 5 minut)<\/td><td>Average (depending on protein composition)<\/td><td>Susceptible to contamination with detergents<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>BCA<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">High (0,005 \u2013 2 mg\/ml)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Long (30 \u2013 60 minut)<\/td><td>High (independent of protein composition)<\/td><td>Susceptible to contamination with reducers<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Summary<\/strong><\/h2>\n\n\n\n<p>The choice of the appropriate protein quantification method depends on the specific characteristics of the sample (e.g. the presence of detergents or interfering substances), the required concentration range, and the time and equipment available.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UV 280 nm<\/strong> is ideal for quick, non-invasive preliminary measurements.<\/li>\n\n\n\n<li><strong>Bradford<\/strong> reigns supreme for the highest sensitivity and speed (in samples without detergents).<\/li>\n\n\n\n<li>For the <strong>highest accuracy<\/strong>, I recommend the <strong>BCA<\/strong> method.<\/li>\n\n\n\n<li>The <strong>Lowry and Microbiurete methods <\/strong>are less commonly used, although Lowry is still used in specific applications.<\/li>\n<\/ul>\n\n\n\n<p><strong>Note: When selecting a measurement technique, remember to consider not only its simplicity and speed, but also its sensitivity and the composition of the samples you want to measure. Choose the method that best suits your needs.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Literature<\/h2>\n\n\n\n<p><strong>K\u0142yszejko-Stefanowicz, L. (red.). (2003). <em>\u0106wiczenia z biochemii<\/em>. Wydawnictwo Naukowe PWN.<\/strong> <\/p>\n\n\n\n<p><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/942051\/\"><strong>Bradford, M. M. (1976). <em>A rapid and sensitive method for the quantitation of microgram quantities of protein&#8230;<\/em><\/strong> <em>Analytical Biochemistry<\/em>, 72(1-2), 248-254. <\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/14907713\/\"><strong>Lowry, O. H., i inni. (1951). <em>Protein measurement with the Folin phenol reagent<\/em>.<\/strong> <em>Journal of Biological Chemistry<\/em>, 193, 265-275. <\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/3843705\/\"><strong>Smith, P. K., i inni. (1985). <em>Measurement of protein using bicinchoninic acid<\/em>.<\/strong> <em>Analytical Biochemistry<\/em>, 150(1), 76-85.<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/bgc.ac.in\/pdf\/study-material\/Keith-Wilson-John-Walker-Principles-and-Techniques-of-Biochemistry-and-Molecular-Biology-Cambridge-University-Press-2010.pdf\"><strong>Wilson, K., Walker, J. (2010). <em>Principles and Techniques of Biochemistry and Molecular Biology<\/em>.<\/strong> <\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Graphics<\/h2>\n\n\n\n<p>Helito, CC BY-SA 4.0 <a href=\"https:\/\/creativecommons.org\/licenses\/by-sa\/4.0\">https:\/\/creativecommons.org\/licenses\/by-sa\/4.0<\/a>, via Wikimedia Commons<\/p>\n\n\n\n<p>Grafika w\u0142asna<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Knowledge of the protein content in a sample is essential in the laboratory. It allows many other laboratory tests (e.g. SDS-PAGE) to be performed correctly&hellip;<\/p>\n","protected":false},"author":1,"featured_media":1178,"parent":1523,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_sitemap_exclude":false,"_sitemap_priority":"","_sitemap_frequency":"","footnotes":""},"class_list":["post-1756","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Protein determination methods - Bioeducator.eu<\/title>\n<meta name=\"description\" content=\"Overview of protein determination methods. 280 nm, Bradford method, BCA, Lowry method, microbiuret method. Mechanism, comparison.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Protein determination methods - Bioeducator.eu\" \/>\n<meta property=\"og:description\" content=\"An overview of protein content determination techniques. Find out what techniques are available, how they work, their advantages and disadvantages, and which one to choose for your purposes.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bioeducator.eu\/?page_id=1756&amp;lang=en\" \/>\n<meta property=\"og:site_name\" content=\"Bioeducator.eu\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-10T10:26:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1024x683.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Protein determination methods - Bioeducator.eu\" \/>\n<meta name=\"twitter:description\" content=\"An overview of protein content determination techniques. Find out what techniques are available, how they work, their advantages and disadvantages, and which one to choose for your purposes.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1024x683.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en\",\"url\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en\",\"name\":\"Protein determination methods - Bioeducator.eu\",\"isPartOf\":{\"@id\":\"https:\/\/bioeducator.eu\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#primaryimage\"},\"image\":{\"@id\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#primaryimage\"},\"thumbnailUrl\":\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-scaled.jpg\",\"datePublished\":\"2025-12-10T10:26:07+00:00\",\"dateModified\":\"2025-12-10T10:26:09+00:00\",\"description\":\"Overview of protein determination methods. 280 nm, Bradford method, BCA, Lowry method, microbiuret method. Mechanism, comparison.\",\"breadcrumb\":{\"@id\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#primaryimage\",\"url\":\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-scaled.jpg\",\"contentUrl\":\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-scaled.jpg\",\"width\":2560,\"height\":1707,\"caption\":\"ELISA test on 96 well plate\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"https:\/\/bioeducator.eu\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Bioeducator &#8211; English\",\"item\":\"https:\/\/bioeducator.eu\/?page_id=590&lang=en\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Baza wiedzy\",\"item\":\"https:\/\/bioeducator.eu\/?page_id=1523&lang=en\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Protein determination methods\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/bioeducator.eu\/#website\",\"url\":\"https:\/\/bioeducator.eu\/\",\"name\":\"Bioeducator.eu\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/bioeducator.eu\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/bioeducator.eu\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/bioeducator.eu\/#organization\",\"name\":\"Bioeducator.eu\",\"url\":\"https:\/\/bioeducator.eu\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/bioeducator.eu\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/03\/Bioeducator_logo_poziom.png\",\"contentUrl\":\"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/03\/Bioeducator_logo_poziom.png\",\"width\":3910,\"height\":935,\"caption\":\"Bioeducator.eu\"},\"image\":{\"@id\":\"https:\/\/bioeducator.eu\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Protein determination methods - Bioeducator.eu","description":"Overview of protein determination methods. 280 nm, Bradford method, BCA, Lowry method, microbiuret method. Mechanism, comparison.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en","og_locale":"pl_PL","og_type":"article","og_title":"Protein determination methods - Bioeducator.eu","og_description":"An overview of protein content determination techniques. Find out what techniques are available, how they work, their advantages and disadvantages, and which one to choose for your purposes.","og_url":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en","og_site_name":"Bioeducator.eu","article_modified_time":"2025-12-10T10:26:09+00:00","og_image":[{"url":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1024x683.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"Protein determination methods - Bioeducator.eu","twitter_description":"An overview of protein content determination techniques. Find out what techniques are available, how they work, their advantages and disadvantages, and which one to choose for your purposes.","twitter_image":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-1024x683.jpg","twitter_misc":{"Szacowany czas czytania":"10 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en","url":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en","name":"Protein determination methods - Bioeducator.eu","isPartOf":{"@id":"https:\/\/bioeducator.eu\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#primaryimage"},"image":{"@id":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#primaryimage"},"thumbnailUrl":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-scaled.jpg","datePublished":"2025-12-10T10:26:07+00:00","dateModified":"2025-12-10T10:26:09+00:00","description":"Overview of protein determination methods. 280 nm, Bradford method, BCA, Lowry method, microbiuret method. Mechanism, comparison.","breadcrumb":{"@id":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bioeducator.eu\/?page_id=1756&lang=en"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#primaryimage","url":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-scaled.jpg","contentUrl":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2023\/01\/cdc-OZcQIhidMTw-unsplash-scaled.jpg","width":2560,"height":1707,"caption":"ELISA test on 96 well plate"},{"@type":"BreadcrumbList","@id":"https:\/\/bioeducator.eu\/?page_id=1756&lang=en#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"https:\/\/bioeducator.eu\/"},{"@type":"ListItem","position":2,"name":"Bioeducator &#8211; English","item":"https:\/\/bioeducator.eu\/?page_id=590&lang=en"},{"@type":"ListItem","position":3,"name":"Baza wiedzy","item":"https:\/\/bioeducator.eu\/?page_id=1523&lang=en"},{"@type":"ListItem","position":4,"name":"Protein determination methods"}]},{"@type":"WebSite","@id":"https:\/\/bioeducator.eu\/#website","url":"https:\/\/bioeducator.eu\/","name":"Bioeducator.eu","description":"","publisher":{"@id":"https:\/\/bioeducator.eu\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bioeducator.eu\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/bioeducator.eu\/#organization","name":"Bioeducator.eu","url":"https:\/\/bioeducator.eu\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/bioeducator.eu\/#\/schema\/logo\/image\/","url":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/03\/Bioeducator_logo_poziom.png","contentUrl":"https:\/\/bioeducator.eu\/wp-content\/uploads\/2025\/03\/Bioeducator_logo_poziom.png","width":3910,"height":935,"caption":"Bioeducator.eu"},"image":{"@id":"https:\/\/bioeducator.eu\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/pages\/1756","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bioeducator.eu\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1756"}],"version-history":[{"count":2,"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/pages\/1756\/revisions"}],"predecessor-version":[{"id":1758,"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/pages\/1756\/revisions\/1758"}],"up":[{"embeddable":true,"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/pages\/1523"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bioeducator.eu\/index.php?rest_route=\/wp\/v2\/media\/1178"}],"wp:attachment":[{"href":"https:\/\/bioeducator.eu\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1756"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}